Home contents
2019
   N# 1 |
2018
   N# 1 | 2 | 3 | 4 | 5 |
2017
   N# 1 | 2 | 3 | 4 | 5 |
2016
   N# 1 | 2 | 3 | 4 | 5 |
2015
   N# 1 | 2 | 3 | 4 | 5 |
2014
   N# 1 | 2 | 3 | 4 | 5 |
2013
   N# 1 | 2 | 3 | 4 | 5 |
2012
   N# 1 | 2 | 3 | 4 | 5 |
2011
   N# 1 | 2 | 3 | 4 | 5 |
2010
   N# 1 | 2 | 3 | 4 | 5 |
2009
   N# 1 | 2 | 3 | 4 | 5 |
2008
   N# 1 | 2 | 3 | 4 | 5 |
2007
   N# 1 | 2 | 3 | 4 | 5 |
2006
   N# 1 | 2 | 3 | 4 | 5 |
2005
   N# | 1 | 2 | 3 | 4 | 5 |
2004
   N# 1 | 2 | 3 | 4 | 5 |
2003
   N# 1 | 2 | 3 | 4 | 5 |
2002
   N# 1 | 2 | 3 | 4 | 5 |
2001
   N# 1 | 2 | 3 | 4 | 5 |
2000
   N# | 1 | 2 | 3 | 4 | 5 |
1999
   N# 1 | 2 | 3 | 4 | 5 |
1998
   N# 1 | 2 | 3 | 5 |
1997
   N# 1 | 2 | 3 | 4 | 5 |
1996
   N# 4 | 5 |

Click on the number of the review to see the content
Teaching bulletin CME
List of all teaching bulletins CME.
Editor reading committee
Editor reading committee.
To publish...
Instructions for authors
Archives Press and Books
Select of books and press articles.
Mailing list
News information letter.
Subscription prices


If you wish to adjust the size of the displayed characters, click in the high menu on "Your account" and choose the desired size.



  Contents > Previous page > Article detail print Download
o Issue N# 4 - 1999 o

PHONIATRICS

A study of vibrato : assessment by panel of judges compared to spectral voice analysis


Authors : D. Morsomme, A Orban, J. Jamart, M. Remacle (Yvoir)

Ref. : Rev Laryngol Otol Rhinol. 1999;120,4:239-244.

Article published in french



Summary : Experts in voice singing and voice training were asked to judge the vibrato of 30 singers (4 samples per singer : a sung [a] held without vibrato ; a sung [a] held with vibrato ; a self-selected passage and an imposed passage. In the first part, they ticked the type of oscillations (vibrato, straight tone, tremolo, quavering...). In the second part, they appraised various criteria. Intra-judge and inter-judge consistencies were determined. The subjective parameters were thereafter correlated with the measurements of six parameters of the MDVP (Multi Dimentional Voice Program). The measurements were carried out on each task. Intra-judge consistency was good for only one judge (67-87 % consistency). Since judge 2 and 3 were hardly reproducible (45-73 % ; 28-57 %) measurement of the inter-judge consistency was pointless. The results of judge 1 were correlated with the Fundamental Tremor Frequency Index, the jitter and the shimmer.



|


Subscribe online - Pay by credit card!